NOTES
S1
2
IN
1
OUT
L1
L2 / N
230V
(
(
115/230 VAC
SELECTION
SWITCH
GREEN NO SHIELD
3. SAME PHASES MUST BE USED TO
POWER VARIABLE FANS AND
CONTROLS ON 3 PHASES POWER.
WHITE - ORANGE
2. PROVIDE SURGE PROTECTION (TO
INCLUDE PROTECTION FROM
LIGHTTNING) FROM POWER SUPPLY
TO CONTROL AND FROM CONTROL TO
OUTPUT EXTENDED PROBE. CONSULT
A CERTIFIED ELECTRICIAN FOR
SPECIFIC RECOMMENDATIONS.
G 1
1. INSTALLATION OF A GOOD QUALITY
ALARM SYSTEM IS STRONGLY ADVISED
TO WARN OF POWER FAILURES AND
HIGH/LOW TEMPERATURES.
CONTROL
SUPPLY
3
4
DO NOT DRILL THIS SIDE
OF THE UNIT CONTROL.
USE AVAILABLE KNOCK
OUTS AT THE BOTTOM OF
THE UNIT.
ELECTRICAL DISTRIBUTION
PANEL
G
L1
4. WE RECOMMAND SEPARATE CIRCUIT
BREAKERS FOR EACH OUTPUT STAGE.
L2 (N)
SAME PHASES MUST BE USED
TO POWER PMV, CVS & FANS.
G
L1
L2 (N)
C/D SERIES
CONTROLLER
Fan Stage 1
10A Mot., 115 VAC (1/2 HP)
230 VAC (1.5 HP)
{
{
CONTROL
POWER SUPPLY
230 VAC (115 VAC)
STAGE 1
POWER SUPPLY
230 VAC (115 VAC)
DISCONNECT
VARIABLE
1 G
EXAMPLE OF SPLIT CONNNECTION
GREEN + SHIELD
WHITE - ORANGE
C/D SERIES
CONTROLLER
PMV-1 #1
PMV-1 #2
Please scan the QR Code to access the complete
manual or visit the website.
Cumberland: http://www.cumberlandpoultry.com
AP: http://www.automatedproduction.com
EN
PMV-1
AP
Cumberland
REV 03
WIRING DIAGRAM
#891-00249
REV 08
GSI Electronics Inc. • 5200 Armand Frappier Saint-Hubert, Qc • Canada J3Z 1G5 • Phone: 1-877-926-2777
E-mail: mtl_techsupport@agcocorp.com
Page 1
ALIMENTATION
DU
CONTRÔLEUR
NOTES
ENTRÉE
SORTIE
L1
L2 / N
230V
2
(
1
NE PAS PERCER LE CÔTÊ
DU CONTRÔLEUR.
UTILISER LES ENTRÊES
PRÊVUES À CET EFFET.
S1
(
4. IL EST RECOMMANDÉ DE RACCORDER
CHAQUE SORTIE DE STAGE À UN
DISJONCTEUR SÉPARÉ.
115/230 VAC
SÉLECTEUR DE
VOLTAGE
VERT PA S DE SHIELD
3. LORS D’UNE ALIMENTATION 3 PHASES,
LES MÊMES PHASES DOIVENT ÊTRE
UTILISÉES POUR ALIMENTER LES
VENTILATEURS VARIABLES ET LE
CONTRÔLEUR.
BLANC - ORANGE
2. DES PROTECTEURS DE SURTENSION SONT
RECOMMANDÉS ENTRE L’ALIMENTATION,
LE CONTRÔLEUR ET LES SONDES.
CONSULTER UN ÉLECTRICIEN AU BESOIN.
G 1
1. L’INSTALLATION D’UN SYSTÈME D’ALARME
EST FORTEMENT RECOMMANDÉE AFIN
DE DÉTECTER LES PERTES DE COURANT
ET LES HAUTES/BASSES TEMPÉRATURES.
3
4
PANNEAU DE DISTRIBUTION
ÉLECTRIQUE
G
LES MÊMES PHASES DOIVENT ÊTRE
UTILISÉES POUR ALIMENTER LES
MODÈLES SUIVANTS : PMV, CVS, &
VENTILATEURS.
L1
L2 (N)
G
L1
L2 (N)
CONTRÔLEUR
SÉRIE C/D
Stage de Ventilation 1
10A Mot., 115 VAC (1/2 HP),
230 VAC (1.5 HP)
{
{
ALIMENTATION DU
CONTRÔLEUR
230 VAC (115 VAC)
ALIMENTATION
STAGE 1
230 VAC (115 VAC)
INTERRUPTEUR
VARIABLE
1 G
EXEMPLE D’UNE CONNECTION MULTIPLE
VERT + SHIELD
BLANC - ORANGE
CONTRÔLEUR
SÉRIE C/D
PMV-1 #1
PMV-1 #2
Veuillez scanner le code QR pour accéder aux
manuels complets ou visiter le site Web.
Cumberland: http://www.cumberlandpoultry.com
AP: http://www.automatedproduction.com
FR
PMV-1
AP
Cumberland
REV 03
SCHÉMA DE BRANCHEMENT
#891-00249
REV 08
GSI Electronics Inc. • 5200 Armand Frappier Saint-Hubert, Qc • Canada J3Z 1G5 • Phone: 1-877-926-2777
E-mail: mtl_techsupport@agcocorp.com
Page 1
">
/
Herunterladen
Nur eine freundliche Erinnerung. Sie können das Dokument direkt hier ansehen. Aber was am wichtigsten ist, unsere KI hat es bereits gelesen. Sie kann komplexe Dinge einfach erklären, Ihre Fragen in jeder Sprache beantworten und Ihnen helfen, auch in den längsten oder kompliziertesten Dokumenten schnell zu navigieren.