LEAVE A CLEARANCE OF AT LEAST 12” TO THE LEFT OF THE CONTROLLER BOX. 115/230 VAC SELECTION SWITCH 12 inches THE CAPACITY OF THE INTERNAL RELAYS IS 10 AMP. WE RECOMMEND INSTALLING EXTERNAL RELAYS ON "ON/OFF" STAGES (FLUORESCENT) DRY CONTACT GND WIRE FROM CONTROL COIL COM COM { COIL POWER SOURCE N.O. N.O. { STAGE OUTPUT TO DISTRIBUTION PANEL STAGE INPUT VARIABLE { POWER SUPPLY 230 VAC (115 VAC) INCANDESCENT OUTPUT MAX. OUTPUT 10 AMP. ON-OFF INCANDESCENT OUTPUT { FLUORESCENT OUTPUT FLUORESCENT OUTPUT MAX. OUTPUT 10 AMP. POWER SUPPLY 230 VAC (115 VAC) { CONTROL POWER SUPPLY 230 VAC (115 VAC) WIRING DIAGRAM VLC-II #891-00161 Rev.04 115/230 VAC SÉLECTEUR DE TENSION CONTACT SEC LA CAPACITÉ DES RELAIS INTERNES EST DE 10 AMP. IL EST RECOMMANDÉ D`INSTALLER DES RELAIS EXTERNES SUR LES STAGES ON-OFF (FLUORESCENT). DU CONTRÔLE BOBINE ALIMENTATION COIL COM COM { FIL GND N.O. N.O. { STAGE SORTIE VARIABLE { AU PANNEAU DE DISTRIBUTION ÉLECTRIQUE STAGE ENTRÉE ALIMENTATION 230 VAC (115 VAC) SORTIE INCANDESCENTE MAX. SORTIE 10 AMP. ON-OFF SORTIE INCANDESCENTE { SORTIE FLUORESCENTE SORTIE FLUORESCENTE MAX. SORTIE 10 AMP. LAISSER UN ESPACE LIBRE D’AU MOINS 12 POUCES À GAUCHE DU CONTRÔLEUR. 12 pouces ALIMENTATION 230 VAC (115 VAC) { ALIMENTATION DU CONTRÔLEUR 230 VAC (115 VAC) SCHÉMA DE BRANCHEMENT VLC-II #891-00161 Rev.04