Exterior Vent Terminal Locations. Regency C34 Classic C34-NG10, C34 Classic C34-LP10
14 |
installation
EXTERIOR VENT TERMINAL LOCATIONS
A
B
C
D
E
F
G
H
Minimum Clearance Requirements
Clearance above grade, veranda, porch, deck, or balcony
Clearance to window or door that may be opened
Clearance to permanently closed window
Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet (61cm)
from the center line of the terminal (check with the local code)
Clearance to unventilated soffit
Clearance to outside corner: with AstroCap Termination Cap.
Clearance to outside corner: with all other approved Termination Caps.
Clearance to inside corner: with AstroCap Termination Cap
Clearance to inside corner: with all other approved Termination Caps.
Clearance to each side of center line extended above meter/regulator assembly
Canada
1
12"(30cm)
12"(30cm)
*
18"(46cm)
12"(30cm)
6"(15cm)
12"(30cm)
6"(15cm)
12"(30cm)
36"(90cm) a
USA
2
12"(30cm)
9" (23cm)
*
18"(46cm)
12"(30cm)
6"(15cm)
12"(30cm)
6"(15cm)
12"(30cm)
*
J
Clearance to service regulator vent outlet 36"(90cm) *
K
L
M
Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance
Clearance to a mechanical air supply inlet (91cm) above if within 10' (3m) horizontally.
Clearance above paved sidewalk or a paved driveway located on public property
12"(30cm)
72"(1.8m)
84"(2.1m)
┼
9" (23cm)
36"(90cm) b
*
N
Clearance under veranda, porch, deck, or balcony 12"(30cm)
‡
*
1
In accordance with current CSA B149.1, Natural Gas and Propane Installation Code
2
In accordance with the current ANSI Z223.1/NFPA 54, National Fuel Gas Code
┼
A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings
‡ Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor
* Clearance in accordance with local installation codes and the requirements of the gas supplier
3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly
b
3 feet (91cm) above - if within 10 feet (3m) horizontally
14 |