B P

Jennifer B.

How to transfer a saved parameter set from the SK PAR-5H ParameterBox to a frequency inverter?

To transfer a parameter set from the SK PAR-5H to a frequency inverter, access the 'Parameter Management' menu and follow these steps: 1. Set parameter P1201 (Copy source) to the desired data set (S1-S5). 2. Set parameter P1202 (Copy destination) to the target frequency inverter (U1-U5). 3. Use parameter P1203 (Start copy) to initiate the transfer and confirm the action on the display. Ensure the target inverter is not in an enabled state during the transfer.

B P

Jennifer B.

How to select a saved parameter set in the SK PAR-5H and transfer it to a frequency inverter?

To transfer parameters, select the source element (S1 to S5) using parameter P1201 'Copy-source'. Then, select the target inverter (U1 to U5) using parameter P1202 'Copy-destination'. Finally, initiate the transmission using parameter P1203 'Start copy' and confirm the prompt. Ensure the target inverter is not enabled during the data transfer.

B P

Jennifer B.

How to transfer a saved parameter set from the SK PAR-5H ParameterBox to a frequency converter?

To transfer a saved parameter set from the ParameterBox SK PAR-5H to your frequency converter, follow these steps: 1. Access the 'Parameter management' menu and use parameter P1201 'Copy-source' to select the source item (S1 to S5). 2. Use parameter P1202 'Copy-destination' to choose the connected frequency converter (U1 to U5) as the transfer target. 3. Use parameter P1203 'Start copy' to initiate the transmission. A confirmation window will appear; validate it to start the process. (Note: Ensure the destination drive is not validating data during the transfer).

B P

Jennifer B.

How to transfer a saved parameter set from the SK PAR-5H ParameterBox to a frequency inverter?

To transfer parameters, access the Parameter Management menu and set parameter P1201 (Copy source) to the desired data set (S1 to S5). Then, set P1202 (Copy destination) to the target frequency inverter (U1 to U5) and use P1203 (Start copy) to initiate the transmission. Confirm the action in the pop-up window. Ensure the destination inverter is not enabled during the transfer.

B P

Jennifer B.

How to transfer a parameter set from the SK PAR-5H ParameterBox to a frequency inverter?

To transfer parameters, first select the source data (S1 to S5) in parameter P1201 'Copy-source'. Next, select the destination inverter (U1 to U5) in parameter P1202 'Copy-destination'. Finally, initiate the transfer via parameter P1203 'Start copy' and confirm the command. Ensure the destination inverter is not enabled during this process.

B P

Jennifer B.

How to select a parameter program from the SK PAR-5H and transfer it to a drive?

Select the source data (S1 to S5) using parameter P1201 'Copy-source', choose the target drive (U1 to U5) in parameter P1202 'Copy-destination', and initiate the transfer using parameter P1203 'Start copy'.

B P

Jennifer B.

How to transfer a parameter set from the SK PAR-5H to a frequency inverter?

Access the parameter management menu. Set parameter P1201 (Copy source) to the desired data set (S1-S5) and parameter P1202 (Copy destination) to the connected frequency inverter (U1-U5). Initiate the transfer using parameter P1203 (Start copy) and validate the confirmation. Ensure the destination inverter is not active during the transfer.

B P

Jennifer B.

How to select a saved program from the SK PAR-5H and transfer it to the frequency inverter?

  1. Go to the Parameter Management menu and use parameter P1201 'Copy-source' to select the data source (S1 to S5).
  2. Use parameter P1202 'Copy-destination' to select the connected frequency inverter (U1 to U5) as the target.
  3. Use parameter P1203 'Start copy' to initiate the transfer and confirm the prompt. Ensure the destination inverter is not enabled during the transfer.