Bul. 140G/140MG
140G-G-F____, 140G-H-F____, 140G-I-F____, 140G-J-F____, 140G-K-F____
Installation instruction for Flex Cable Operator for 140G-G through K
Istruzioni di installazione
Installationsanleitung
Instructions pour l’installation
Instrucciones de instalación
Installation - Installazione - Instalación
Instalação WARNING: To prevent electrical shock, disconnect from power source before
installing or servicing. Install in suitable enclosure. Keep free from contaminants.
(Follow NFPA70E requirements).
AVVERTENZA: Per prevenire infortuni, togliere tensione prima dell'installazione o
manutenzione. Installare in custodia idonea. Tenere lontano da contaminanti.
(Seguire i requisiti NFPA70E).
WARNUNG: Vor Installations- oder Servicearbeiten Stromversorgung zur
Vermeidung von elektrischen Unfällen trennen. Die Geräte müssen in einem
passenden Gehäuse eingebaut und gegen Verschmutzung geschützt werden. (Befolgen
Sie die Anforderungen nach NFPA70E).
AVERTISSEMENT: Avant le montage et la mise en service, couper l'alimentation
secteur pour éviter toute décharge. Prévoir une mise en coffret ou armoire appropriée.
Protéger le produit contre les environnements agressifs. (Vous devez respecter la
norme NFPA70E).
ADVERTENCIA: Desconéctese de la corriente eléctrica, antes de la instalación o
del servicio, a fin de impedir sacudidas eléctricas. Instálelo en una caja apropiada.
Manténgalo libre de contaminantes. (Cumpla con los requisitos NFPA70E).
ATENÇÃO: Para evitar choques, desconectar da corrente elétrica antes de fazer a
instalação ou a manutenção. Instalar em caixa apropriada. Manter livre de
contaminantes. (Cumpra as exigências da norma NFPA70E).
M4 x .7 x 12 mm
PN-227250
DIR 10000873178 (Version 02)
1/4-20 x .71 in
K
C
LA
C
#6-32 x .312 in
Ue>0V
> 1.0” (25 mm)
R > 6.0” (150 mm)
1-3/32"
(32 mm)
1-3/32"
(32 mm)
1-1/4" Min.
(32 mm)
5/16"
(7.9 mm)
1/2"
(12.7 mm)
1/4"
(6.35 mm)
Square corners or
up to 1/4" (6.35 mm) radius
1-1/4" Min.
(32 mm)
1" Min.
(25.4 mm Min.)
4-11/16"
(119 mm)
3-1/2"
(89 mm)
Right Hand Flange
PN-227250
DIR 10000873178 (Version 02)
15" Min.
(381 mm)
(2) .265" (7 mm) Dia. Holes
Left Hand Flange
(2)
1
140G-G
140G-I
1
G
I
0.984 in
(25.0 mm)
4.213 in
(107.0 mm)
1.378 in
(35.0 mm)
4.803 in
(122.0 mm)
M4
M4
10 - 15 in lbs
1.2 - 1.7 Nm
140G-H
140G-J
140G-K
1
J
H
1.181 in
(30.0 mm)
4.370 in
(111.0 mm)
K
1.378 in
(35.0 mm)
1.831 in
(46.5 mm)
5.472 in
(139.0 mm)
6.929 in
(176.0 mm)
M4
M4
10 - 15 in lbs
1.2 - 1.7 Nm
PN-227250
DIR 10000873178 (Version 02)
M5
(3)
2
10 - 15 in lbs
1.2 - 1.7 Nm
T-20
3
PN-227250
DIR 10000873178 (Version 02)
(4)
4
2
1
3
23 - 37 in lbs
2.6 - 4.2 Nm
7/16"
(11 mm)
1
5
10 - 15 in lbs
1.2 - 1.7 Nm
#1
PN-227250
DIR 10000873178 (Version 02)
(5)
2
6
Trip Breaker
K
C
LA
C
C D
7
Reset Breaker
A
8
PN-227250
DIR 10000873178 (Version 02)
(6)
8
K
AC
Breaker On
CL
B
9
K
C
LA
Breaker Off
C
A
Done
PN-227250
DIR 10000873178 (Version 02)
(7)
A
C
3/4"
(19 mm)
B
D
3/4"
(19 mm)
Rockwell Automation maintains current product environmental information on its website at http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page.
Allen-Bradley, Rockwell Software, and Rockwell Automation are trademarks of Rockwell Automation, Inc.
Trademarks not belonging to Rockwell Automation are property of their respective companies.
Publication 140G-IN128C-MU-P - June 2014
PN-227250
DIR 10000873178 (Version 02)
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Printed in USA.
">