Danfoss ETS 175L Electric Expansion Valve_ETS , 250L, 400L Guide d'installation
PDF
Document
Installation guide Compatible refrigerants / Kältemittel Kompatibilität / Fluides compatibles / Compatibilidad de refrigerantes / 适用的冷媒: Inlet fluid temperature / Eingangstemperaturbereich / entrée température du fluide / entrada temperatura líquida / 入口流体温度: Max. working pressure / Max. zul. Betriebsüberdruck / Pression de service max. / Presión de trabajo máx. / 最大工作压力 (gauge): R134a, R404A, R407A, R407C, R407F, R407H, R410A, R417A, R422A, R422B, R422D, R438A, R442A, R448A, R449A, R449B, R450A, R452A, R463A, R507A, R513A, R513B, R515A, R515B, R1234ze(E), R1234yf*, R516A* Min. -40 °C / -40 °F Max. 70 °C / 158 °F Max. 95 °C / 203 °F for ETS 500L and oil free valves MWP = 37 bar / 536 psig Allowable ambient temperature / Zulässige Umgebungstemperatur / Température ambiante admissible / Temperatura ambiente permisible / 允许的环境温度: Min. -40 °C / -40 °F Max. 70 °C / 158 °F Total number of steps: / Max. Schritte: / Nombre de pas total: / Número de pasos total: / 总步数: Nominal voltage / Nennspannung / Tension nominale / Voltaje nominal / 名义电压: Resistance / Widerstand / résistance électrique / Resistencia / 电阻: Phase current / Phasenstrom / Phase électrique / Corriente de fase / 相电流: 12 V DC 52.4 Ohm ±10% @ 25 OC Recommended: 200 mA at 200 pps 034R9828 034R9828 Electric Expansion Valve Type ETS 175L, ETS 250L, ETS 400L, ETS 500L NOTE: For more details check datasheet. * only for oil free valves ETS 175L and 250L Bipolar Flow Direction / Durchflussrichtung / Sens d’écoulement / Dirección del flujo / 流向: ETS 175L, ETS 250L, ETS 400L 3810 full steps ETS 500L 4999 full steps Application / Anwendung / Application / Aplicación / 应用: Імпортер:ТОВ з іі “Данфосс ТОВ” 04080, Київ 80, п/с 168, Україна ETS 175L / 250L Normal Reverse ETS 400L / 500 L Normal Reverse 1 | © Danfoss | Climate Solutions | 2022.12 AN361477117710en-000402 Info for UK customers only: Danfoss Ltd., 22 Wycombe End, HP9 1NB, GB Stepper motor type / Schrittmotortype / Type de moteur pas à pas / Tipo de motor a pasos / 步进电机形式: Danfoss 27H254.10 Mounting / Einbau / Montage / Installación / 安装: Brazing / Einbau / Montage /Installación / 安装: N2 Max. 110 °C / 230 °F Danfoss 27H254.10 Max. 700 °C / 1300 °F N2 gas from opposite side of soldering point. Schutzgas gegenüber der Lötstelle einströmen lassen. Refroidissement gaz ci-contre site de point de soudure. Corriente de N2 desde el lado opuesto a la soldadura. 氮气保护从阀门焊接口的另一侧通入. Electrical connections / Elektrische Anschlüsse / Connexions électriques / Conexiones eléctricas/ 电气连接: ETS 400L / 500L Coil A B1 Coil B A2 CLOSING Coil A A1 Coil B A1 A2 B1 B2 1 + - + - 2 + - - + 3 - + - + 4 - + + - OPENING B2 ETS 175L / 250L © Danfoss | Climate Solutions | 2022.11 AN361477117710en-000402 | 2 Disassembling / Zerlegung / Désassemblage / Desmontaj / 拆卸: 1 ETS 400L / 500L 2 3 Screw X 8 Screw T30 ETS 175L / 250L Screw X 4 Screw T30 A ETS 400L / 500L ETS 175L / 250L Assembling / Zusammenbau / Assemblage / Montaje / 安装: 2 1 New 4 3 6 ±0.5 Nm (for ETS 175L/250L) 5.3 ±0.5 Nm (for ETS 400L / 500L) ETS 400L / 500L Screw X 8 Screw T30 B Screw X 4 Screw T30 A ETS 175L / 250L © Danfoss | Climate Solutions | 2022.11 AN361477117710en-000402 | 3 Warning! / Achtung! / Attention! / Advertencia! / 警告! . Do not connect directly to AC/DC power source. Connect valve to appropriate controller/driver only. Do not operate valve while assembling or disassembling . Bitte den ETS nicht direkt mit einer Spannungsquelle (Gleich- oder Wechselstrom) verbinden. Schließen Sie das Ventil nur an geeignete Regler/Steuergeräte an. Ventil bitte nicht in zerlegtem Zustand ansteuern. . Ne pas raccorder directement le moteur à une alimentation AC / DC. Raccorder la vanne au régulateur approprié. Ne pas actionner la vanne pendant le montage ou le démontage. . No aplicar tensión directamente a la válvula. Conectar la válvula a un controlador/driver adecuado. No haga funcionar la válvula durante el montaje o desmontaje. . 请仅将阀门连接于合适的控制器/驱动器,勿直接与交流或直 流 电源连接。在安装和拆卸阀门时请勿操作电子膨胀阀。 Special note for R1234ze(E), R1234yf and R516A: Ignition risk is evaluated in accordance to ISO5149/EN378 and IEC60335-2-40. - Do not use valve outside of the stated temperature limits. - Do not unplug when energized - Must be installed in a suitable end use enclosure to protect the valve electrical plug against moisture, dust, dirt and impact. - For countries where safety standards are not an indispensable part of the safety system Danfoss recommend the installer to get a third party approval of the system containing flammable refrigerant. © Danfoss | Climate Solutions | 2022.11 AN361477117710en-000402 | 4 ">
/
Download
Just a friendly reminder. You can view the document right here. But most importantly, our AI has already read it. It can explain complex things in simple terms, answer your questions in any language, and help you quickly navigate even the longest or most compilcated documents.